HVAC Validation and Clean Room Validation

The various parameters to be evaluated for the validation of heating, ventilation, and air conditioning (HVAC ) system include air flow pattern, air flow velocity, air changes per hour, filter leak test, particle count, viable monitoring, filter integrity test, pressure difference, recovery test for temperature and humidity, temperature and humidity uniformity

hvac-validation-and-clean-room-validation
Offerings Technical Specification Description
Biosafety Cabinet Validation
Hepa Filter Integrity Test For 2 HEPA filters Inflow Velocity Test For 9 Samples Downflow Velocity Test For 8 Samples Particle Count Test For 5 locations Air Flow Pattern Test For one test Noise Level Test For one test Lux Level Tests For one test
Hepa Filter Integrity Test For 2 HEPA filters using Aerosol Photometer - (TEC Services PH-5) Inflow Velocity Test For 9 Samples using Anemometer (TSI - 9545-A-5725) Downflow Velocity Test For 8 Samples using Anemometer (TSI - 9545-A-5725) Particle Count Test For 5 locations using Particle Counter - (TSI - 9350-03) Air Flow Pattern Test For one test using Air Flow Pattern Tester - (TVSPL - FPT 500) Noise Level Test For one test using Noise Level Meter - (Lutron-SL-4010) Lux Level Tests For one test using Lux Meter - (Kusam Meco)
Cleanroom Validation
Air Balancing (Supply Air Terminal) Per HEPA filter Pressure Balancing (Return Air Terminal) Per Return Air Riser HEPA Filter Integrity/ Leakage Test per HEPA filter Non-Viable Particle Count per Location Room Recovery Test per Location Temp. and RH Mapping for 24Hrs for 10 locations Min. 10 locations Airflow Pattern Test (Flow Pattern at SA and RA Terminal) per HEPA filter Total AHU Balancing Per AHU
"Air Balancing (Supply Air Terminal) Per HEPA filter Pressure Balancing (Return Air Terminal) Per Return Air Riser using Anemometer (TSI - 9545-A-5725)- Digital Manometer (TSI - 8380) HEPA Filter Integrity/ Leakage Test per HEPA filter using Aerosol Photometer - (TEC Services PH-5) Non-Viable Particle Count per Location using Particle Counter - (TSI - 9350-03) Room Recovery Test per Location using Particle Counter - (TSI - 9350-03) Temp. and RH Mapping for 24Hrs for 10 locations Min. 10 locations Using Data Loggers Airflow Pattern Test (Flow Pattern at SA and RA Terminal) per HEPA filter using Air Flow Pattern Tester - (TVSPL - FPT 500) Total AHU Balancing Per AHU
Laminar Air Flow and Reverse LAF Validation
Air Velocity Test / ACPH Calculation For 4 HEPA filters Hepa Filter Integrity Test For 4 HEPA filters Particle Count Test For 2 locations Air Flow Pattern Test For one test Recovery Test Per Location
Air Velocity Test / ACPH Calculation For 4 HEPA filters using Anemometer (TSI - 9545-A-5725) Hepa Filter Integrity Test For 4 HEPA filters using Aerosol Photometer - (TEC Services PH-5) Particle Count Test For 2 locations using Particle Counter - (TSI - 9350-03) Air Flow Pattern Test For one test using Air Flow Pattern Tester - (TVSPL - FPT 500) Recovery Test Per Location using Particle Counter - (TSI - 9350-03)
Operation Theater Validation
Air Velocity Test / ACPH Calculation Per HEPA filter Hepa Filter Integrity Test Per HEPA filter Pressure Balancing Per Return Air Riser Particle Count Test per Location Recovery Test per Location Air Flow Pattern Test Per Return/supply Air terminal Temp. and RH Mapping for 24Hrs for 6 locations Min. 10 locations
Air Velocity Test / ACPH Calculation Per HEPA filter using Anemometer (TSI - 9545-A-5725)- Air capture hood (TSI-8380). Hepa Filter Integrity Test Per HEPA filter using Aerosol Photometer - (TEC Services PH-5) Pressure Balancing Per Return Air Riser using Anemometer (TSI - 9545-A-5725)- Digital Manometer (TSI - 8380) Particle Count Test per Location using Particle Counter - (TSI - 9350-03) Recovery Test per Location using Particle Counter - (TSI - 9350-03) Air Flow Pattern Test Per Return/supply Air terminal using Air Flow Pattern Tester - (TVSPL - FPT 500) Temp. and RH Mapping for 24Hrs for 6 locations Min. 10 locations Using Data Loggers
Positive Air Pressure Module Validation
Air Velocity Test / ACPH Calculation (01 Nos) Air Velocity Test / ACPH Calculation (01 Nos) For one HEPA filter Hepa Filter Integrity Test (01 Nos) For one HEPA filter Particle Count Test (only if unit is connected to Cleanroom) (02 Nos) For 2 locations Flow Pattern Test (only if unit is connected to Cleanroom) For one HEPA filter Noise Level Test For one test for one HEPA filte
Air Velocity Test / ACPH Calculation (01 Nos) For one HEPA filter using Anemometer (TSI - 9545-A-5725) Hepa Filter Integrity Test (01 Nos) For one HEPA filter using Aerosol Photometer - (TEC Services PH-5) Particle Count Test (only if unit is connected to Cleanroom) (02 Nos) For 2 locations using Particle Counter - (TSI - 9350-03) Flow Pattern Test (only if unit is connected to Cleanroom) For one HEPA filter using Air Flow Pattern Tester - (TVSPL - FPT 500) Noise Level Test For one test using Lux Meter - (Kusam Meco)