Medical Equipment Calibration

Medical Equipment Calibration is the process of configuring the measurement and the accuracy of the medical device or the medical system used in Hospitals. This field intends to offer advance healthcare treatment, including diagnosis, monitoring and therapy.

The medical calibration measurements, is important because they establish whether the medical devices are appropriate, according to the international standards or not. The calibration also helps to minimise misdiagnosis caused by poorly calibrated machine. It is very important to configure hospital systems, according to the standard calibration because these machines need to be absolutely accurate since it is a matter of life and death.

Offerings Technical Specification Description
BP Apparatus
All Ranges
Manometer and Leak test
Defibrillator Calibration
Calibration of all ranges
Energy, ECG, Charging time and Electrical safety
ECG Machines Calibration
Calibration of all ranges
HV testing, Leakage Current test, Earth Bond, Resistance
Electrosurgical Diathermy (Cautery Machines) Calibration
Calibration of all ranges
Electrical safety test, ESU output Power, Current, Peak to peak voltage, crest factor
Fetal Monitor Calibration
Calibration of all ranges
Electrical safety and IUP
Hemotherm Calibration
Calibration of all ranges
Temperature Calibration
Incubator Analyzer Calibration
Humidity: 30 to 90 %RH
Sound Level: 94 dB
Temperature: 10 to 50 °C
Calibration of Fluke INCU-2
Calibration parameters Pressure, Flow rate, TIME, Temperature, RH, Airflow
Infusion Pump Analyzer Calibration
Flow Rate: 10 ml/hr. to 1000 ml/hr. Flow Volume: 5 ml to 400 ml
Calibration of Fluke IDA1-S,
IDA4, IDA5, IDA4 Plus, IDA5
Calibration parameters: Flow rate, Flow Volume, Pressure
NIBP Analyzer Calibration
pressure: 0 to 500mmHg
Calibration parameters: Pressure, leak rate
O T Lamp, Light Sources Calibration
Calibration of all ranges
Lux Measurement
O2 Analyzer Calibration
21% and 100% of O2
Calibration of Fluke Max O2
Pacemaker Analyzer Calibration
Resistance: 0 to 1500ohm
Calibration of Fluke Sigmapace1000
Calibration parameters: Voltage, Resistance, Current
Pacemaker Calibration
Calibration of all ranges
Demand and asynchronous Mode
Patient Monitors Calibration
Calibration of all ranges
ECG, Spo2, NIBP, respiration, Electrical safety
Phototherapy Calibration
Calibration of all ranges
Temperature Calibration, Electrical safety
Physiotherapy Equipment Calibration
Calibration of all ranges
Electrical safety
Pulse Oximeters Calibration
Calibration of all ranges
Spo2, Electrical safety
SPo2 Functional Tester Calibration
SPO2: 30 to 100%
Calibration of Fluke Index 2
Spo2 Verification
SPO2: 30 to 100%
Oxygen Saturation verification
Syringe Pumps and Infusion Pumps Calibration
Calibration of all ranges
Flow, Occlusion, PCA Bolus, Volume, Electrical safety Test
Tourniquets Calibration
Calibration of all ranges
Pressure calibration
Ventilator Calibration and Anesthesia Machine Calibration
Calibration of all ranges
Electrical safety and 21 Ventilator Parameter like Tidal volume, I: E Ratio, Rate, PEEP etc.
Warmers and Patient Incubators Calibration
Calibration of all ranges
Temperature Calibration