NABL Certified Calibration Services Pune – India | Clean Room Validation Services | Biomedical Calibration Services

Textile Calibration

There are many quality tests that textiles products go through before they come into the market. When it comes to the complexity of textile equipment calibration, it takes the expertise of a highly skilled calibration company to achieve the industry specifications. We calibrate the equipment’s/ machines that assure the operators to perform those tests with confidence. Our calibrations are essential for the machines providing high performance tests.

Offerings Technical Specification Description
Abrasion Tester Calibration
Weights 9 Kpa – 433 gms
Weights 12 Kpa – 630 gms
Inner Diameter – Pilling 24.0 mm
Outer Diameter – Abrasion 60.5 mm
RPM 47.5
Diameter of Sample Cutter 140 mm
Diameter of Sample Cutter 38mm
Abrasion Tester Diameter of Sample Cutter
Abrasion Tester Diameter of Sample Cutter
Abrasion Tester Inner Diameter – Pilling
Abrasion Tester Outer Diameter – Abrasion
Abrasion Tester RPM
Abrasion Tester Weight
ASTM Impact Tester (Charpy) Calibration
All parameter calibration
NIST sample, Support Anvils set, and Charpy Striker must available in stock with customer. (ASTM Impact Tester (Charpy))
Bursting Strength Tester Calibration
Pressure Gauge 124, 81, and 55.2 psi Inner Diameter 30.5 mm Calculation of test area 7.3 cm2
Pressure Gauge Inner Diameter Calculation of test area
Crock meter Calibration
Rubbing downward force 918gm
Diameter of finger peg 16mm
Diameter of finger, stroke length, counts and Mass
Dura Wash Calibration
Temperature 40, 50, 60°C Timer 15 min
Temperature Timer
Electrolux Dryer Test Cycle Calibration
Test Cycle 90Min
Exhaust Temperature 80°C
Cool down 1min
Test Cycle Exhaust Temperature Cool down
Govmark Flammability Tester Timer Calibration
1 sec
Govmark Flammability Tester Timer Calibration
Perspirometer Weights Calibration
3.17 Kg and 3.61 kg
Weights calibration
Pilling Tester Calibration
Pilling tube (mass) 10 gm
Dimension of pilling tube 15x2mm
Pilling tube (mass) Dimension of pilling tube
TEAR TESTER Calibration
Distance between clamping jaws 2.8mm
Specimen tearing tester 15mm
Pendulum with weight 3200, 6, 1600, 400gm
Distance between clamping jaws Specimen tearing tester Pendulum with weight
Tumble Dryer Calibration
Time 60Min
Temperature
Cotton Sturdy 66 °C
Delicate < 60°C
Permanent 66°C
Time and Temperature Calibration
Universal wear Tester Stroke motion Calibration
115rpm
Speed Calibration
Vertical Flammability Tester Timer Calibration
5, 10 Sec
Time calibration by Comparison Method
Washer /Washing Machine/Dryer Calibration
Washer Agitating Speed Normal cycle – 179 spmA
Washer Agitating Speed Delicate cycle - 119 spm
Washer Agitating Speed Permanent cycle – 179 spm
Washer Final Spin Speed Time Normal cycle – 6 min
Washer Final Spin Speed Time Delicate cycle – 4 min
Washer Final Spin Speed Time Permanent Cycle – 4 min
Washer Spinning Speed of Washer Normal cycle – 645 rpm
Washer Spinning Speed of Washer Delicate cycle – 430 rpm
Washer Spinning Speed of Washer Permanent cycle – 430 rpm
Washer Agitating Speed
Washer Final Spin Speed Time
Washer Spinning Speed of Washer
Wira Steam Timer Calibration
30 sec
Time calibration by Comparison Method
Wrist action Shaker Temperature Calibration
35, 50, 70°C
Temperature calibration